Info
Net2 is a networked PC-controlled access control system with the advantages of centralized control, event logging and flexible control of user access options. Each door control unit is part of a network. However, it can be operated independently of other components, make its own decisions and record events.
The Net2 Nano control panel uses wireless technology developed by Paxton Access to connect to the central PC running the Net2 software. Net2 Nano control panels can be used in conjunction with Net2 Classic and Net2 Plus control panels and can be integrated into existing Net2 installations. This is particularly useful in places where cabling is difficult.
Installation
There is a label on the Net2 Nano door control unit on which the connections for the reader, door opener, power supply, etc. are clearly indicated by color coding. The device has a dedicated output for an electric strike (incl. integrated diode) and a voltage-free relay output for switching any electric strike, other opening drive or electronic device. Exit buttons, door contacts, tamper switches and alarm devices can be connected.
The door control units transmit the data to the PC via the Net2Air USB interface or the Net2Air Ethernet interface. Paxton Access supplies products to determine the required wireless range at a site prior to installation. The corresponding connections are equipped with diagnostic LEDs, which are helpful for a trouble-free installation.
Technical data
- Door control unit in plastic housing for wall mounting
- Communication via radio, frequency: 2.4 Ghz
- Readers / keypads can be connected on the entry and exit side, but without differentiation
- Floating output for door opener or similar: 12 V DC, max. 1.1 A
- Relay contact for control unit, door opener: or similar: Switching capacity: 2 A at 24 V DC
- Door contact, tamper contact, exit button and EV monitoring can be connected
- Local alarm transmitter can be connected (up to max. 1 A current consumption)
- Can be operated online and offline
- Storage of the last 3,584 events in real time in offline mode
- Self-detection and diagnostic LEDs for time-saving commissioning
- Flash EEPROM for central firmware updates
- Operating voltage: 12 V DC
- Current consumption: Max. 120 mA
- Dimensions (W x H x D): 105mm x 106mm x 23mm