Paxton Net2 Entry - Control center

  • Net2 plus control center
  • 4-port PoE switch for easy expansion
  • Sabotage switch for additional security
  • 2A 12V DC power supply unit
  • Battery backup (not included)
  • Plastic housing
Available immediately

Order within the next 2 days and 16 hours and 16 minutes and you will receive your order between 16.7. and 17.7.
UPS Delivery Icon DHL Delivery Icon
Paxton Net2 Entry - Control center

Info
The Entry control unit is the central interface between a door station and the door and supplies the monitors with data and power via PoE. The ports can also be used to extend the network of door stations and monitors using Entry extension switches or to connect the control unit to a Net2 system running Net2 v4.25 or higher.

Installation
Entry components can be easily connected using Cat5 or standard RJ45 patch cables. Entry can also use an existing network infrastructure for easy installation. Since power and data are supplied via PoE over the same cable, a separate power supply is not required.

Operation
A visitor initiates a video call via the bell button on the external door station. Access can then be granted to the visitor via the Entry Monitor with its intuitive touchscreen user interface. The indoor monitor can be used either with the handset (for private calls) or in hands-free mode.

When connected to Net2, access to the building can be enabled via PIN or code entry and/or a proximity transponder.

Technical data

  • Control unit with integrated Net2 plus door control unit
  • Up to 100 control units for door stations in one system
  • Compatible with other Net2 products from Paxton
  • With integrated PoE switch for 4 PoE devices (e.g. Net2 Entry door station and Net2 Entry Monitor)
  • Networked door control unit for one door (decentralized intelligence and high operational reliability)
  • Module, pre-assembled in plastic housing with regulated 2A power supply
  • Communication via TCP/IP and/or RS485
  • Terminal block for integration with an intruder alarm system
  • Relay contact for door opener or similar, switching capacity: 5 A at 50 V DC
  • Relay contact for control unit, switching capacity: 5 A at 50 V DC
  • Door contact, tamper contact, exit button and EV monitoring can be connected
  • Local alarm transmitter can be connected (up to max. 1 A current consumption)
  • Can be operated online and offline
  • Storage of the last 2,728 events in real time in offline mode
  • Self-detection and diagnostic LEDs for time-saving commissioning
  • Flash EEPROM for central firmware updates
  • Operating voltage: 230 V AC / 12 V DC
  • Current consumption: Max. 200 mA
  • Space for 1 emergency power battery 12 V DC, 7.2 Ah
  • Dimensions (W x H x D): 236 x 320 x 80 mm